Solution 07 / 07
Existing Facility Upgrade / Retrofit
Most facilities are improved, not built new. ALVEDA SOLUTIONS assesses what the existing building and systems can support, defines the changes that close the gaps, and plans the works so production and qualified status are protected.

The problem and its context
Upgrades are usually triggered by an inspection finding, a new product, a capacity increase or a change in the regulatory basis. Each trigger needs a different scope, and the existing structure, plant room space and shutdown windows limit what can be done.
A retrofit that is not phased properly can disrupt more production than it protects. The work has to be sequenced around live operations, with clear change control and a defined requalification scope.
Typical pressure points
- Separating what must change from what can stay
- Structural, ceiling-height and plant-room limits of the existing building
- Short shutdown windows and work next to live production
- Keeping qualified status and change control intact through the works
What the solution involves
- 01
Gap assessment of the facility, HVAC, utilities and flows against the target basis
- 02
Prioritised corrective actions with engineering options and their impact
- 03
Retrofit design for zoning, cleanrooms, HVAC and utilities within existing constraints
- 04
Phasing and shutdown planning around production
- 05
Construction support next to live operations
- 06
Defined requalification scope for the affected areas and systems
Engineering path
The service disciplines involved, in the order the project needs them. Each step links to the full service description.
- 01GMP gap assessment and CAPA planningGaps identified against the target basis, with prioritised corrective actions.
- 02Facility upgrade and retrofit engineeringUpgrade options that fit the existing structure and operations.
- 03Revised zoning and flowCorrected personnel, material and waste routes within the existing footprint.
- 04Cleanroom refurbishmentEnvelope, finishes and details upgraded to the required classification.
- 05HVAC retrofit and rebalancingAir handling, filtration and pressure regimes brought in line with the basis.
- 06Pressure cascade correctionPressure relationships re-established between the affected rooms.
- 07Utility upgradesCapacity and quality of utilities raised to the new demand.
- 08Detailed retrofit engineeringConstruction packages with tie-ins, phasing and shutdown sequences.
- 09Construction support in live operationsSite coordination, segregation of works and protection of running areas.
- 10Requalification of affected areasRequalification scope defined by the change and its impact.
- 11Upgrade project managementSchedule, shutdown windows and interfaces with operations.
Deliverables and design basis
Typical deliverables
- Gap assessment report against the target basis
- Prioritised CAPA and upgrade options
- Retrofit design packages
- Phasing and shutdown plan
- Construction support records
- Requalification scope and plan
Key design-basis considerations
- Trigger for the upgrade: findings, new product, capacity or basis change
- Existing drawings, as-built condition and system performance
- Structural, ceiling-height and plant-room constraints
- Production schedule and acceptable shutdown windows
- The target regulatory basis and change-control requirements
Classification, pressure relationships and containment are set by the project regulatory basis and the process risk.
How the regulatory design basis is setNext step
Planning this type of facility?
Share the product, the capacity and where the project stands. An engineer will reply with a proposed engineering path.